Artevino Single-Zone Cooling Failure in Dual-Zone System

Dual-zone cabinet: one zone cools properly while the other remains warm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan in one zone, Blocked air duct between zones, Faulty zone sensor, Partial refrigerant restriction affecting one evaporator

How to Fix / Troubleshooting

Safety: Unplug the cabinet before opening interior panels.

  • Identify affected zone: Compare actual bottle temperatures in both zones.
  • Check zone fan: Listen and visually confirm fan operation in the warm zone. Replace the fan motor if not running.
  • Inspect air ducts: Ensure vents between zones are not blocked by shelves or bottles.
  • Test zone sensor: Measure resistance of the NTC sensor in the warm zone and compare to the working zone. Replace if readings differ significantly.
  • Sealed system: If fans and sensors are good but one evaporator remains warm, a sealed-system issue may exist and requires a professional technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Evaporator Fan / Zone Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements