E10
Artevino Main Control Board Power Supply Fault

Display shows E10 and the unit may shut down or fail to start, sometimes accompanied by a clicking sound from the control area.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed low-voltage power supply on main PCB, Shorted component on control board, Loose mains connector, Surge damage to electronics

How to Fix / Troubleshooting

Safety: Unplug the appliance. Capacitors on the control board can retain charge; avoid touching bare solder joints.

  • Check mains connection: Inspect the power cord, plug, and internal terminal block for loose connections or burn marks. Tighten screws if needed.
  • Visual inspection of PCB: Remove the control board cover (usually at the rear or behind the top panel). Look for swollen capacitors, burnt resistors, or cracked solder joints.
  • Reseat connectors: Disconnect and reconnect all harnesses to the main PCB to ensure good contact.
  • Test output voltages: If you are qualified, power the unit and measure the low-voltage outputs (e.g., 5V, 12V) from the board. If missing or unstable, the board is defective.
  • Replace main control board: Transfer each connector one by one from the old board to the new Artevino-compatible PCB to avoid miswiring. Secure the board and reassemble covers.
  • Test operation: Restore power and verify that E10 is cleared and the cabinet starts normally.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board (PCB)
Check Price on Amazon