E3
Artevino
Ambient / Room Temperature Sensor Failure
Display shows E3 and temperature reading is clearly inaccurate (e.g., shows 5°C while interior feels warm).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty ambient NTC sensor, Wiring harness damage between ambient sensor and PCB, Sensor dislodged from its mounting near air intake, Moisture damage on sensor connector
How to Fix / Troubleshooting
Safety: Disconnect the Artevino cabinet from mains power before accessing the control panel or sensor wiring.
- Identify ambient sensor location: On many Artevino wine coolers, the ambient sensor is located near the front grille or behind the top control panel, sensing room temperature.
- Inspect sensor and mounting: Ensure the sensor is not hanging loose inside the cabinet or pressed against cold surfaces, which can cause incorrect readings.
- Check wiring: Follow the small-gauge wires from the sensor to the main control board. Look for pinched or cut insulation, especially where the harness passes through metal openings.
- Test the sensor: With a multimeter, measure resistance at room temperature. Compare to expected NTC values (similar to cabinet sensor). If reading is out of range, replace the sensor.
- Replace ambient sensor: Remove any retaining clips, install the new Artevino-compatible ambient NTC, and route wiring away from hot compressor or condenser areas.
- Reset and test: Reconnect power, clear the error by power-cycling, and verify that E3 does not return and that displayed temperature tracks room conditions more accurately.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.