Artevino
No Power / Dead Appliance
Unit does not power on at all; display is blank and no interior light.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown internal fuse on main PCB, Faulty power cord, Loose mains terminal block, Failed main control board power supply
How to Fix / Troubleshooting
Safety: Ensure the outlet is de-energized or unplug the unit before opening any electrical compartments.
- Check outlet: Test the wall socket with another appliance or a tester to confirm power is present.
- Inspect power cord: Look for cuts, kinks, or burn marks. Replace the cord if damaged.
- Access terminal block: Remove the rear panel to locate the mains terminal block. Tighten any loose screws and inspect for heat damage.
- Internal fuse: Many Artevino boards include a small fuse. Check it with a multimeter and replace with the same rating if blown. If it blows again immediately, a short exists and the board or wiring must be replaced.
- Replace main PCB: If the fuse is good but there is still no low-voltage output or display, replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Power Cord / Main Control Board
Check Price on Amazon