E13
Balay Fan Tachometer or Speed Feedback Fault

Display shows E13 and the internal fan speed is erratic or reported incorrectly; sometimes accompanied by noise warnings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fan motor with failed tachometer output, Broken tach wire in fan harness, Connector issue at main PCB, Faulty tach input circuit on control board

How to Fix / Troubleshooting

Safety: Unplug the unit before touching the fan or wiring.

  • Access fan assembly: Remove interior panels to reach the evaporator fan.
  • Inspect fan connector: Many Balay fans have three wires (power, ground, tach). Ensure the connector is fully seated and wires are intact.
  • Test fan operation: With power restored briefly, observe if the fan starts smoothly. If it stalls or pulses, the motor may be failing.
  • Replace fan: If the tach output is not present or the fan is unstable, replace the fan motor with a Balay-compatible tach fan.
  • Control board: If a new fan does not clear E13, the tach input on the PCB may be defective and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor (with Tach Output)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements