E5
Balay Compressor Start/Overload Protection Fault

Wine cooler shows E5 and the compressor does not start; fans may run but no cooling occurs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay or PTC, Open thermal overload protector, Locked or seized compressor, Faulty main control board compressor drive relay

How to Fix / Troubleshooting

Safety: Unplug the appliance. Work only on the electrical start components; do not open the sealed refrigeration system. If you are not comfortable with mains voltage, contact a technician.

  • Access compressor compartment: Remove the rear lower service panel to expose the compressor, start device, and main control board.
  • Inspect start device: The PTC relay/overload assembly is mounted on the compressor terminals. Check for burn marks, melted plastic, or a burnt smell. Replace if damaged.
  • Test continuity: With the unit unplugged, remove the start device and test the overload protector for continuity. If open when cool, replace the start device assembly.
  • Check compressor windings: Measure resistance between the three compressor pins. All readings should be finite and not shorted to ground. If windings are open or shorted, the compressor is defective and requires professional replacement.
  • Control board relay: If the compressor and start device test good, inspect the main PCB for a stuck or burnt compressor relay. Replacement of the PCB should be done by a qualified technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay/Overload Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements