E6
Balay Evaporator/Interior Fan Motor Fault

Display shows E6 and the internal fan does not run; uneven temperature distribution and warm spots inside the cabinet.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DC fan motor, Obstructed fan blades by ice or debris, Loose or damaged fan wiring harness, Faulty fan driver circuit on main control board

How to Fix / Troubleshooting

Safety: Disconnect power before working near the fan or evaporator. Fan blades can be sharp.

  • Access the fan: Remove shelves and the rear interior panel to expose the evaporator fan assembly.
  • Check for obstructions: Look for ice buildup, packaging material, or wires touching the fan blades. Clear any obstruction and ensure the fan spins freely by hand.
  • Inspect wiring: Verify that the fan connector is fully seated and that wires are not cut or pinched.
  • Test the fan motor: With the fan disconnected and the unit unplugged, measure resistance across the motor terminals. An open circuit indicates a failed motor. For DC fans, you can also briefly power with a suitable low-voltage DC supply if you are experienced.
  • Replace the fan: If defective, remove mounting screws, swap in a Balay-compatible evaporator fan motor, and reconnect wiring.
  • Control board check: If the fan is good but never receives voltage when the compressor is running, the main PCB fan driver may be faulty and should be replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.