Balay
Control Logic / Start Inhibit Fault
Wine cooler display is on but compressor and fan never start; temperature remains at room temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect temperature setpoint (too warm), Demo/showroom mode enabled, Faulty door switch reporting door open, Failed compressor relay on PCB
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
- Check settings: Ensure the cooler is not in demo or showroom mode (refer to Balay user manual for key combination to exit). Set a colder temperature and wait 10–15 minutes.
- Door status: Verify the door switch is working and that the control panel does not indicate an open door when closed.
- Listen for relay click: When the unit should start cooling, listen for a click from the control board. No click may indicate a failed relay or control board.
- Professional repair: If settings and door switch are correct but the compressor never receives power, the main PCB or relay must be replaced by a technician.