Balay
Short Cycling of Compressor
Wine cooler frequently turns on and off in very short cycles (short cycling).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect thermostat differential settings (firmware), Oversensitive or poorly placed sensor, Failing compressor start device, Control board relay issue
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing electrical components.
- Check ambient conditions: Avoid placing the cooler in very hot or very cold environments that can cause rapid cycling.
- Sensor placement: Ensure the cabinet NTC is not directly in the cold air stream or touching metal surfaces.
- Inspect start device: Check the compressor start relay/overload for signs of overheating and replace if suspect.
- Control board: If cycling persists, the control algorithm or relay may be faulty, requiring PCB replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Start Relay/Overload Assembly
Check Price on Amazon