Blomberg
Single-Zone Cooling Failure in Dual-Zone System
Dual-zone wine cooler: upper zone cools but lower zone is warm (or vice versa).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator fan for affected zone, Faulty zone temperature sensor, Air duct blockage between zones, Zone-specific control relay failure on PCB
How to Fix / Troubleshooting
Safety: Unplug the wine cooler before removing interior panels.
- Identify affected zone: Determine which zone is not cooling and note any error indications.
- Check fan operation: Remove the interior panel for the affected zone and verify that its evaporator fan runs when cooling is demanded. Replace the fan motor if not operating.
- Inspect air ducts: Ensure that air passages between the evaporator and the zone are not blocked by ice or packaging material.
- Test zone sensor: Measure resistance of the zone's temperature sensor and compare to specifications. Replace if out of range.
- Control board: If fan and sensor are good, the zone's control relay or triac on the main PCB may be faulty. Replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Zone Evaporator Fan Motor or Zone Temperature Sensor