Blomberg
Thermostat / Temperature Control Failure
Wine cooler interior too cold; bottles very chilled or freezing even at normal setpoint.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty cabinet temperature sensor reading too warm, Stuck compressor relay on main PCB, Miscalibrated control board, Shorted sensor wiring
How to Fix / Troubleshooting
Safety: Unplug the appliance before accessing sensors or the control board.
- Confirm setpoint: Verify the displayed set temperature is appropriate. Adjust to a higher temperature and see if compressor run time decreases.
- Check sensor placement: Ensure the cabinet NTC sensor is properly mounted and not touching the evaporator directly, which can cause incorrect readings.
- Test sensor: Measure resistance of the cabinet sensor and compare to NTC specifications. Replace if out of range.
- Inspect control relay: On the main PCB, check the compressor relay for signs of welding or sticking. If the compressor runs continuously regardless of setpoint, replace the main control board.
- Verify with thermometer: Use an accurate thermometer inside the cabinet to confirm actual temperature after repairs.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor (NTC) or Main Control Board
Check Price on Amazon