Blomberg
Loose Components or Tubing Vibration
Wine cooler makes rattling or clanking noise when compressor starts or stops.
Advertisements
Possible Causes
Loose condenser coil or mounting brackets, Refrigerant lines contacting each other, Loose compressor mounting hardware, Items on top of cabinet vibrating
How to Fix / Troubleshooting
Safety: Unplug the unit before adjusting any components at the rear.
- Check external items: Remove any bottles, glasses, or objects from the top of the wine cooler that may rattle.
- Secure condenser and brackets: Tighten any loose screws or brackets holding the condenser coil and fan assembly.
- Isolate tubing: Gently bend copper lines so they do not touch each other or the cabinet. Use foam sleeves or clips to prevent metal-on-metal contact.
- Compressor mounts: Verify that the compressor mounting bolts are properly tightened and that rubber grommets are not cracked or missing. Replace grommets if worn.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements