Blomberg
Compressor Not Running
Wine cooler not cooling at all; interior light works but temperature remains at room temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor start relay/PTC, Open thermal overload on compressor, Faulty main control board not sending power to compressor, Open wiring between control board and compressor
How to Fix / Troubleshooting
Safety: Unplug the wine cooler before removing the rear panel. Sealed system work should be done only by certified technicians.
- Listen for compressor: With the unit plugged in and calling for cooling, listen at the back. If the compressor is silent and no vibration is felt, proceed with checks.
- Check start device and overload: Remove the start relay and overload from the compressor terminals. Inspect for burn marks or rattling components. Test for continuity; replace with a compatible Blomberg start device/overload if defective.
- Verify power to compressor: With extreme caution and using proper insulated probes, check for mains voltage at the compressor terminals when the unit should be cooling. If no voltage is present, the main PCB or wiring may be faulty.
- Control board: If the compressor and start components test good but never receive power, the main control board likely needs replacement.
- Compressor failure: If the compressor hums briefly then clicks off repeatedly even with a new start device, the compressor may be locked or internally damaged. Contact a professional for sealed system repair or replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start Device / Overload Protector
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements