Blomberg
Reduced Cooling Capacity / Sealed System Inefficiency
Wine cooler runs continuously but does not reach set temperature; interior is cool but not cold enough.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coils restricting heat rejection, Weak or failing compressor, Refrigerant leak in evaporator or tubing, Condenser fan not running at full speed
How to Fix / Troubleshooting
Safety: Unplug the unit before cleaning or accessing the rear compartment.
- Clean condenser: Remove dust and lint from condenser coils with a brush and vacuum. Ensure the rear or front grille is not blocked.
- Check condenser fan: Verify the fan near the compressor runs whenever the compressor runs and that it spins at full speed. Replace the condenser fan motor if slow or not running.
- Verify installation: Ensure adequate clearance around the wine cooler per Blomberg specifications. Overcrowded cabinetry can cause overheating.
- Monitor frost pattern: With the rear interior panel removed briefly, observe the evaporator coil. A healthy system will frost evenly across most of the coil. A partial frost pattern or only at the inlet suggests a sealed system issue (leak or restriction) requiring professional service.
- Professional diagnosis: If airflow and installation are correct but performance remains poor, contact an authorized technician for sealed system testing and possible refrigerant recharge or component replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.