Blomberg
No Power / Electrical Supply Fault
Wine cooler will not power on at all; display and lights are off.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker or blown fuse, Faulty wall outlet, Damaged power cord, Failed main control board power supply
How to Fix / Troubleshooting
Safety: Do not attempt repairs on live circuits. Unplug the unit before inspecting the cord or internal components.
- Check outlet: Plug a lamp or other device into the same outlet to verify power. Reset any tripped breakers or GFCI outlets.
- Inspect power cord: Examine the cord for cuts, burns, or kinks. If damaged, replace the cord with the correct Blomberg part.
- Test at terminal block: With the rear panel removed and power disconnected, locate the power terminal block or connector on the main PCB. Verify that connections are tight and not burnt.
- Main PCB: If power is present at the board input but there is no display or response, the main control board's power supply may have failed. Replace the main PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Power Cord or Main Control Board
Check Price on Amazon