BODEGA43 Temperature Calibration / Sensor Drift

Displayed temperature is significantly different from the actual temperature measured with a thermometer.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aging NTC sensor, Poor sensor placement, Loose sensor mounting on evaporator, Control board calibration error

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors.

Steps:

  • Verify with reliable thermometer: Place a calibrated thermometer in the center of the cabinet away from walls and compare after several hours of stable operation.
  • Inspect sensor placement: Ensure the cabinet sensor is properly clipped to its mounting point and not touching the evaporator directly unless designed to.
  • Replace sensor: If the sensor consistently reads off by a large margin, replace the cabinet temperature sensor (NTC).
  • Control calibration: Some models allow minor calibration via service mode; refer to BODEGA43 documentation or contact support.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Temperature Sensor (NTC Probe)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements