dE
BODEGA43 Door Switch or Door Sensor Fault

Display shows dE and the interior light or fans may turn off unexpectedly; unit may think the door is open when it is closed.

Advertisements

Possible Causes

Failed magnetic reed switch, Misaligned door magnet, Broken door switch wiring, Faulty door sensor input on PCB

How to Fix / Troubleshooting

Safety: Unplug the wine cooler before removing trim or accessing the door switch wiring.

Steps:

  • Identify door sensor type: Many BODEGA43 models use a magnetic reed switch in the cabinet frame and a magnet in the door.
  • Check magnet alignment: Verify that the magnet in the door aligns with the switch location when the door is closed. Adjust the door or magnet position if necessary.
  • Test the switch: Access the reed switch (often behind a small plastic cover in the frame). With a multimeter on continuity, place the magnet near the switch; the reading should change from open to closed.
  • Inspect wiring: Follow the switch wires to the main control board. Look for breaks or loose connectors.
  • Replace components: If the switch does not respond to the magnet, replace the door reed switch. If the magnet is missing or weak, replace the door magnet.

After repair: Restore power and confirm that the dE code clears when the door is closed and that the interior light and fans operate normally.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Reed Switch / Door Magnet
Check Price on Amazon

We may earn a commission from links on this page.