E2
BODEGA43 Evaporator Temperature Sensor Failure

Display shows E2 and the compressor or fan may not run correctly; temperature drifts or one zone is much warmer than expected.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator NTC sensor, Sensor shorted by moisture or ice, Broken sensor harness near evaporator, Oxidized connector at main PCB

How to Fix / Troubleshooting

Safety warning: Always unplug the BODEGA43 wine cooler before removing rear or interior panels. Sharp metal edges can cause injury—wear cut-resistant gloves.

Diagnostic steps:

  • Power cycle: Disconnect power for 5 minutes, then reconnect. If E2 reappears, proceed.
  • Locate the evaporator sensor: Remove interior shelves and the rear inner plastic cover over the evaporator coil. The evaporator NTC is usually clipped directly to the evaporator tubing or mounted in a small plastic holder on the coil.
  • Inspect for ice and moisture: Heavy frost or ice buildup can damage the sensor or its wiring. Carefully defrost with the unit unplugged—do not use sharp tools; use warm air or allow time to melt.
  • Check wiring: Follow the sensor leads from the evaporator to the cabinet pass-through and then to the main control board at the back. Look for chafed insulation, broken wires, or loose connectors.
  • Measure resistance: At room temperature, the evaporator NTC should read similar to the cabinet sensor (typically 5–10 kΩ). A reading of OL (open) or near 0 Ω indicates a failed sensor.
  • Replace the sensor: If faulty, install a new evaporator temperature sensor (NTC) designed for BODEGA43 wine coolers. Clip it securely to the evaporator coil in the same position to ensure accurate defrost control.
  • Reassemble and test: Refit the evaporator cover, restore power, and monitor for several hours to confirm that E2 does not return and that cooling is stable.

Note: If the sensor tests good but E2 persists, the main control board sensor circuit may be defective and require replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Temperature Sensor (NTC Probe)
Check Price on Amazon