E8
BODEGA43 Compressor Drive or Main Control Board Fault

Display shows E8 and the unit may not cool; compressor does not start even though the display appears normal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor relay on main PCB, Burnt PCB trace in compressor circuit, Internal control board failure, Incorrect voltage supply to compressor

How to Fix / Troubleshooting

Warning: This fault involves high-voltage circuits. If you are not experienced with electrical diagnostics, contact a qualified technician.

Basic checks (user level):

  • Power supply: Confirm the outlet provides stable voltage using another appliance. Avoid extension cords or power strips.
  • Reset: Unplug the cooler for 10 minutes, then reconnect. If E8 returns immediately, a control fault is likely.

Advanced checks (technician level):

  • Access main PCB: Remove the rear lower panel to locate the main control board.
  • Inspect for damage: Look for burnt components, darkened areas, or swollen capacitors near the compressor relay.
  • Check compressor output: With the unit powered and calling for cooling, measure AC voltage at the compressor terminals (extreme caution). No voltage with E8 present suggests a failed relay or board.
  • Relay test: Some boards allow relay replacement; others require full board replacement.

Resolution: In most cases, the fix is to replace the main control board (PCB) with a genuine BODEGA43 part. Label all connectors before removal to ensure correct reinstallation.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements