BODEGA43 Excessive Vibration / Mechanical Noise

Wine cooler makes loud rattling or vibrating noises during operation.

Advertisements

Possible Causes

Unit not leveled, Loose compressor mounting bolts, Vibrating condenser tubing against cabinet, Internal fan blades hitting wiring or panels

How to Fix / Troubleshooting

Safety: Unplug the unit before adjusting internal components. Use caution when tilting the cooler.

Steps:

  • Level the unit: Adjust the front leveling feet so the BODEGA43 cooler is stable and does not rock. Use a spirit level if available.
  • Check external contact: Ensure the cabinet is not touching walls, cabinets, or other appliances that can amplify vibration.
  • Rear inspection: Remove the rear panel and check that the compressor mounting grommets and bolts are secure but not overtightened.
  • Secure tubing: Look for copper or aluminum refrigerant lines touching the cabinet or each other. Gently bend them away and add foam or rubber spacers if needed.
  • Fan noise: Inspect condenser and evaporator fans for contact with wires or panels. Reposition wiring and tighten fan mounts.
Advertisements

Repair Difficulty

Easy 2/5
Advertisements