Possible Causes
Aging NTC sensor, Poor sensor placement or contact, Control board calibration error, Sensor wiring resistance change
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing sensors or the control board.
Steps:
- Verify with a reliable thermometer: Place a calibrated thermometer in the center of the cabinet away from walls and compare readings after several hours.
- Inspect sensor placement: Ensure the cabinet sensor is properly clipped to the evaporator cover or wall and not touching the evaporator directly unless designed to.
- Replace sensor: If readings are consistently off by several degrees, replace the cabinet NTC sensor.
- Control board replacement: If a new sensor does not correct the discrepancy, the control board's calibration may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet NTC Temperature Sensor
Check Price on Amazon