E13
Bosch
Humidity Sensor or Humidification System Failure
Display shows E13 and the humidity function does not operate correctly (on models with humidity control)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective humidity sensor, Disconnected humidity sensor harness, Failed humidification module, Faulty control board humidity circuit
How to Fix / Troubleshooting
Safety: Disconnect power before accessing the humidity sensor or module.
Steps to address E13:
- Identify humidity components: On Bosch models with humidity control, the sensor is usually located in the upper interior area, and a small humidification module may be present.
- Inspect sensor: Check for visible damage, corrosion, or moisture accumulation on the sensor.
- Check wiring: Ensure the sensor harness is securely connected to the control board.
- Replace sensor or module: If the sensor is faulty or the humidification module does not operate when commanded, replace the defective component with the correct Bosch part.
- Control board check: If new components do not resolve E13, the main control board may be at fault and should be replaced by a professional.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor
Check Price on Amazon
We may earn a commission from links on this page.