Bosch Drainage or Condensation Management Failure

Water pooling at the bottom of the wine cooler or on the floor in front

Advertisements

Possible Causes

Clogged condensate drain hole, Disconnected or kinked drain tube, Excessive humidity and frequent door openings, Cracked drain pan

How to Fix / Troubleshooting

Safety: Unplug the unit before working inside or behind it. Wipe up any standing water to prevent slipping.

Steps:

  • Locate drain hole: Inside the cabinet, find the small drain hole at the rear (often just above the compressor area).
  • Clear blockage: Use a soft pipe cleaner or flexible plastic rod to gently clear any debris or mold from the drain hole.
  • Check drain tube and pan: From the rear, inspect the drain tube leading to the evaporator pan above the compressor. Ensure it is not kinked or disconnected. Verify the pan is not cracked.
  • Level the unit: Adjust leveling feet so water flows toward the drain and not out the door.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Drain Tube
Check Price on Amazon