Bosch Thermostat or Temperature Sensor Out of Calibration

Wine cooler runs constantly and is too cold, bottles freezing or forming ice crystals

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted NTC temperature sensor, Stuck relay on main control board, Incorrect temperature calibration, Faulty control panel

How to Fix / Troubleshooting

Safety: Disconnect power before accessing sensors or the control board.

Steps:

  • Verify set temperature: Ensure the setpoint is appropriate for wine (typically 5–18°C / 41–64°F depending on type).
  • Check with a thermometer: Place an accurate thermometer inside to compare actual temperature to display. Large differences suggest sensor or control issues.
  • Inspect and test sensor: Locate the cabinet NTC sensor and measure resistance at known temperatures. Replace if readings are out of Bosch specification.
  • Control board evaluation: If the sensor is good but the compressor never cycles off, the compressor relay on the main PCB may be stuck closed. Replace the main control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.