Brandt Dual-Zone Control or Damper Failure

Dual-zone Brandt wine cooler: temperatures of both zones are the same and cannot be controlled independently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty dual-zone control board, Stuck air damper between zones, Shared sensor misreading, Wiring fault between zones

How to Fix / Troubleshooting

Safety first: Unplug the cooler before internal inspection.

Steps to restore independent zone control:

  • 1. Verify settings: Confirm that each zone is set to a different temperature and that the display accepts the settings.
  • 2. Control reset: Perform a full power reset by unplugging for 10 minutes.
  • 3. Check damper: Access the partition between zones and inspect the air damper mechanism. Ensure it moves freely and is not stuck open.
  • 4. Sensor check: Test each zone's temperature sensor. A failed sensor can cause the control to default to a single temperature.
  • 5. Control board: If mechanical parts are fine, the dual-zone control logic on the main PCB may be faulty and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Damper Assembly