E1
Brandt
Cabinet Temperature Sensor (NTC) Failure
Digital display shows E1 and cabinet is not cooling or cooling poorly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open-circuit NTC sensor, Shorted NTC sensor, Damaged sensor harness, Faulty main control board
How to Fix / Troubleshooting
Safety first: Unplug the wine cooler from the mains before removing any panels. Do not work on live circuits.
Steps to check and replace the cabinet temperature sensor (NTC):
- 1. Power reset: Unplug the unit for 5 minutes, then plug it back in. If E1 returns immediately, proceed with diagnosis.
- 2. Locate the cabinet sensor: On most Brandt wine coolers, the cabinet NTC is clipped to the evaporator cover or mounted on the rear interior wall behind a small plastic cover. Remove interior shelves and the rear plastic panel if necessary.
- 3. Inspect wiring: Check the sensor leads and connector going to the main PCB (usually behind the rear metal service panel). Look for broken wires, corrosion, or loose connectors. Reseat the connector firmly.
- 4. Test the sensor: With a multimeter set to resistance (kΩ), measure the NTC across its two leads at room temperature (around 20–25°C). A typical Brandt NTC will read between 5–20 kΩ. If it reads open (OL) or near 0 Ω, the sensor is defective.
- 5. Replace the sensor: If readings are out of range, order a compatible Brandt cabinet NTC sensor. Disconnect the old sensor, route the new sensor along the same path, secure it with clips or tape, and reconnect to the PCB.
- 6. Reassemble and test: Refit the interior panel and shelves, restore power, and monitor the display. The E1 code should clear automatically after a short period if the fault is resolved.
- 7. If E1 persists: With a known-good sensor installed, a persistent E1 usually indicates a faulty main control board. At this point, replacement of the PCB or professional service is recommended.