E8
Brandt Control Panel Communication Error

Display shows E8 and the unit may shut down or not respond to controls.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose control panel ribbon cable, Damaged touch control PCB, Faulty main control board, Moisture ingress in control panel

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel or top cover. Avoid static discharge to electronic boards.

Steps to address E8 communication faults:

  • 1. Power cycle: Unplug the cooler for 10 minutes, then reconnect. If E8 reappears immediately, proceed with inspection.
  • 2. Access control panel: Remove the top trim or front control panel screws. Carefully pull the panel forward to expose the ribbon cable or wiring harness.
  • 3. Check connections: Ensure the ribbon cable between the user interface board and main PCB is fully seated and not damaged. Reseat both ends.
  • 4. Inspect for moisture: Look for signs of condensation or liquid damage on the control PCB. Dry gently with a soft cloth and allow time to air dry completely.
  • 5. Visual inspection of boards: Check for burnt components, cracked solder joints, or corrosion on both the control panel PCB and main control board.
  • 6. Replace faulty board: If reseating cables does not resolve the issue, replace the user interface board first (most common). If E8 persists, the main control board may also need replacement.
  • 7. Reassemble and test: Refit the control panel, restore power, and verify that all buttons respond and the error code is cleared.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

User Interface Control Board
Check Price on Amazon

We may earn a commission from links on this page.