Brandt Compressor Short Cycling

Wine cooler short cycles: compressor starts and stops frequently within a few minutes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheating compressor, Faulty overload protector, Incorrect thermostat sensing, Poor ventilation around unit

How to Fix / Troubleshooting

Safety first: Unplug the cooler before touching the compressor or electrical components.

Steps to address short cycling:

  • 1. Improve ventilation: Ensure the cooler has proper airflow around the condenser and compressor. Move it away from walls if necessary.
  • 2. Clean condenser coil: Dust buildup can cause overheating. Clean thoroughly as described earlier.
  • 3. Check ambient temperature: Extremely high room temperatures can cause overload trips. If possible, relocate to a cooler area.
  • 4. Inspect overload protector: Access the compressor and check the overload device. If it is discolored or rattles, replace it with a Brandt-compatible part.
  • 5. Sensor placement: Ensure the cabinet temperature sensor is correctly positioned and not directly in the airflow of the evaporator fan, which can cause rapid cycling.
  • 6. Professional diagnosis: If short cycling persists, the compressor may be failing internally or the control board may be malfunctioning. Seek professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Overload Protector
Check Price on Amazon