Café Stuck Door Switch or Control Logic Fault

Interior light stays on even when the door is closed, causing warming and glare.

Advertisements

Possible Causes

Failed door switch stuck closed, misaligned door magnet, shorted light relay on control board

How to Fix / Troubleshooting

Safety first: Unplug the unit before working on the door switch or control board.

  • Step 1 – Confirm door closure: Ensure the door is fully closed and aligned. Adjust leveling legs if needed.
  • Step 2 – Test door switch: Locate the door switch and test continuity with the door open and closed (or magnet present). Replace the switch if it does not open when the door is closed.
  • Step 3 – Check magnet alignment: Verify the door magnet lines up with the switch location. Adjust the door or switch position as needed.
  • Step 4 – Inspect control board: If the switch is working but the light remains on, the light relay on the main control board may be stuck. Replace the Café-compatible main control board.

After repair, close the door and verify that the light turns off and the cabinet cools properly.