Caple
Door or Temperature Alarm Nuisance Trigger
Alarm beeping frequently without obvious reason, sometimes with flashing display
Advertisements
Possible Causes
Door not fully closed, Faulty door switch, Temperature sensor reading unstable, Control PCB alarm circuit oversensitive
How to Fix / Troubleshooting
Safety: No internal work is needed to silence the alarm temporarily, but unplug before accessing switches or boards.
Steps to stop nuisance alarms:
- Check door closure: Ensure the door is fully closed and not obstructed by shelves or bottles.
- Inspect door switch: Test the door switch or reed sensor as described in the always-on light fault; replace the door switch if it does not reliably change state.
- Monitor temperature: Use a thermometer to confirm that the cabinet is actually within the set range. If not, investigate cooling performance.
- Sensor stability: If the temperature fluctuates rapidly on the display, test and replace the cabinet NTC sensor if necessary.
- Control PCB: Persistent false alarms with correct sensors and switch may indicate a faulty main control PCB.
Tip: Some models allow alarm muting via the control panel; consult the user manual for the mute procedure.