Caple Compressor Start or Control Relay Failure

Interior fan runs but compressor never starts, cabinet warms up

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty compressor start relay, Open compressor overload protector, Failed compressor winding, Faulty compressor relay on main control PCB

How to Fix / Troubleshooting

Safety: Unplug the cooler before accessing the compressor or control board.

Diagnostic steps:

  • Listen for relay click: When the unit calls for cooling, you should hear a click from the control PCB and then the compressor starting. No click may indicate a PCB issue.
  • Inspect start components: Remove the compressor terminal cover and check the start relay and overload for damage. Replace the compressor start relay/overload if suspect.
  • Measure compressor windings (advanced): With components removed and power off, measure resistance between compressor terminals. Open windings indicate a failed compressor.
  • Control PCB: If the compressor and start components test good but never receive power, the compressor relay on the main control PCB may be faulty and the board should be replaced.

Note: Compressor electrical testing should only be done by those familiar with safe multimeter use.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay / Overload Protector
Check Price on Amazon