Caple Dual-Zone Airflow or Control Fault

Temperature in upper and lower zones is the same despite different setpoints

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed zone divider or damper, Internal fan not circulating correctly, Incorrect sensor placement between zones, Faulty dual-zone control PCB

How to Fix / Troubleshooting

Safety: Unplug the unit before removing internal panels.

Steps to restore dual-zone operation:

  • Verify model: Confirm your Caple model is truly dual-zone; some are single-zone with multiple displays.
  • Check airflow paths: Inspect the internal divider between zones for blocked vents or missing baffles.
  • Inspect internal fan: Ensure the circulation fan is running and that air can move between the evaporator and both zones.
  • Sensor check: Confirm that each zone's NTC sensor is installed in the correct compartment and not swapped or dislodged.
  • Control PCB: If hardware is correct but both zones track the same temperature regardless of settings, the dual-zone control logic on the main control PCB may be faulty and require replacement.

Tip: Use separate thermometers in each zone to confirm actual temperatures before replacing parts.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.