Caple
No Power / Electrical Supply Fault
Wine cooler will not power on at all, display is blank
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown household fuse or tripped breaker, Faulty mains power cord, Failed main control PCB power supply, Loose internal mains connections
How to Fix / Troubleshooting
Safety: Always unplug from the wall before opening any electrical covers. If you suspect a wiring fault, consider professional help.
Steps to restore power:
- Check outlet: Test the wall socket with another appliance to confirm it has power. Reset any tripped breakers.
- Inspect plug and cord: Look for cuts, kinks, or burn marks on the power cord. Replace the mains power cord if damaged.
- Internal fuse: Some Caple models have an internal fuse on the main control PCB. Remove the PCB cover and check for a blown fuse; replace only with the same rating.
- Check connections: Ensure the mains input wires are securely fastened to the PCB terminals and that there are no signs of overheating.
- Replace control PCB: If the fuse is good and power is present at the board but the display remains dead, the main control PCB is likely faulty and should be replaced.
Warning: Do not bypass fuses or operate the unit with exposed live parts.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements