Compressor Short Cycling Control / Thermostat Fault
Compressor runs continuously without cycling off; cabinet may be too cold or still not at setpoint.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty temperature sensor misreading warm, Main PCB not stopping compressor, Door gasket leak causing constant heat gain, Ambient temperature outside design range
How to Fix / Troubleshooting
Safety: Continuous running can overheat components. Monitor for unusual smells or noises and unplug if present.
- Check actual temperature: Use a separate thermometer to compare with the display. If the cabinet is already at or below setpoint but the compressor keeps running, suspect a sensor or control fault.
- Inspect gasket and door alignment: Correct any misalignment and replace damaged gaskets.
- Test NTC sensor: Verify that the cabinet sensor resistance matches expected values. Replace if out of range.
- Control board: If the sensor is good but the compressor never stops, the relay on the PCB may be stuck closed. Replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board