E4
Climadiff
Defrost Sensor / Defrost Circuit Fault
Display shows E4 and the unit may run continuously or not at all, with defrost issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective defrost NTC sensor on evaporator, Broken wiring to defrost sensor, Shorted or open defrost heater causing abnormal readings, Main PCB defrost control failure
How to Fix / Troubleshooting
Safety: Disconnect mains power before accessing internal components. Surfaces around the evaporator can be sharp.
- Access evaporator area: Remove the internal rear panel to expose the evaporator and defrost components.
- Locate defrost sensor: The defrost NTC is usually clipped to the evaporator tubing or attached near the defrost heater.
- Check for ice buildup: Heavy ice accumulation can damage the sensor or wiring. Fully defrost the unit if necessary.
- Test sensor: Measure resistance at a known temperature (e.g., after defrost at room temperature). Compare to the NTC curve. Replace if open/shorted.
- Inspect heater and wiring: Check the defrost heater for continuity and inspect wiring harnesses for burns or breaks.
- Replace faulty parts: Install a new defrost sensor (and heater if needed) using original clips and insulation. Ensure good thermal contact with the evaporator.
- Reassemble and test: Refit panels, restore power, and monitor for correct defrost cycles and absence of the E4 code over 24 hours.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Defrost NTC Sensor
Check Price on Amazon