E7
Climadiff Condenser Fan Motor Fault

Display shows E7 and the condenser fan at the rear does not operate correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Burned-out condenser fan motor, Fan blades blocked by debris, Loose wiring or connector at fan, Main PCB fan output failure

How to Fix / Troubleshooting

Safety: Unplug the wine cooler before removing the rear service panel.

  • Inspect the fan: Remove the rear panel and locate the condenser fan near the compressor and condenser coil. Check for dust, plastic wrap, or other debris blocking the blades.
  • Spin test: Turn the fan blades by hand. They should rotate freely without grinding. If stiff or seized, the motor is likely faulty.
  • Check wiring: Ensure the fan connector is firmly seated on the harness and that no wires are cut or melted.
  • Electrical test: Measure continuity of the fan motor. Replace the fan if open or shorted.
  • Replace fan assembly: Install a new condenser fan motor with the correct bracket and blade orientation. Secure wiring away from hot or moving parts.
  • Test operation: Restore power and verify that the fan starts when the compressor runs and that the E7 code disappears.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon