H1
Climadiff High Temperature Alarm / Overtemperature Condition

Display shows H1 and the cabinet temperature reading is extremely high or flashing.

Advertisements

Possible Causes

Door left open or not sealing, Failed compressor or low refrigerant charge, Condenser blocked or fan not running, Temperature sensor reading abnormally high

How to Fix / Troubleshooting

Safety: Ensure the unit is in a well-ventilated area. If you smell burning, unplug immediately.

  • Check door and gasket: Make sure the door closes fully and the gasket seals all around. Look for warped doors or torn gaskets and replace if needed.
  • Verify ventilation: Confirm that the rear and sides have adequate clearance and that grilles are not blocked.
  • Inspect condenser and fan: Clean dust from the condenser coil and ensure the condenser fan runs when the compressor is on.
  • Monitor compressor: Listen and feel for the compressor running. If it is silent or cycles off quickly, there may be a compressor or control fault.
  • Check sensor plausibility: Compare displayed temperature with an independent thermometer inside the cabinet. If the display is much higher than actual, suspect a sensor issue (see E1/E2).
  • Allow recovery: After correcting airflow or door issues, allow 12–24 hours for the temperature to stabilize. The H1 alarm should clear automatically once the setpoint is reached.