Climadiff Temperature Calibration / Sensor Placement Issue

Temperature displayed on the control panel does not match an independent thermometer inside the cabinet.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sensor not properly clipped to evaporator or wall, NTC sensor drifted out of calibration, Poor air circulation around sensor, Control board calibration offset

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal panels.

  • Verify with multiple points: Place a reliable thermometer in the middle of the cabinet away from walls and compare after several hours.
  • Check sensor mounting: Remove the interior panel and ensure the NTC sensor is correctly clipped in its designated position, not hanging loose.
  • Replace sensor if needed: If readings are consistently off by several degrees and other causes are ruled out, replace the NTC sensor.
  • Compensate in use: If the difference is small and stable, you may choose to adjust the setpoint to achieve the desired actual temperature.