Costway Short Cycling / Control or Overload Issue

Compressor short cycles (turns on and off frequently) with minimal cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty temperature sensor causing rapid cycling, Oversensitive overload protector, Control board logic fault, Poor ventilation causing overheating

How to Fix / Troubleshooting

Safety: Unplug before accessing electrical components.

Steps:

  • Improve ventilation: Ensure adequate clearance around the unit and clean the condenser coil.
  • Monitor cycling: Note run times. Very short runs (less than 2–3 minutes) suggest control or overload issues.
  • Check sensor: Test and replace the cabinet temperature sensor if readings are unstable.
  • Inspect overload: Test the compressor overload protector. Replace if it trips at normal operating temperatures.
  • Control board: If hardware is good, replace the main control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Overload Protector
Check Price on Amazon

We may earn a commission from links on this page.