CF
Costway
Condenser Fan Error (Compressor Models)
Wine cooler displays CF and cooling performance is poor or intermittent.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed condenser fan motor, Fan blade obstructed by dust or debris, Loose fan connector, Faulty fan driver on main control board
How to Fix / Troubleshooting
Safety: Unplug the unit before removing the rear panel.
Steps:
- Access the condenser fan: Remove the rear lower panel to expose the condenser fan motor and coil.
- Clean and inspect: Remove dust buildup from the fan and condenser coil. Ensure the fan blade spins freely by hand.
- Check wiring: Confirm the fan connector is firmly seated on the control board and that wires are not damaged.
- Test operation: Briefly power the unit and observe whether the fan starts when the compressor runs. If not, test for voltage at the fan connector. Replace the fan motor if voltage is present but the fan does not run.
- Control board: If no voltage is present and wiring is intact, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.