Low Temperature Alarm / Over-Cooling Condition
Display shows L1 and interior temperature is too cold; bottles may be over-chilled.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck relay on main control board, Shorted temperature sensor reading too warm, Control board calibration error
How to Fix / Troubleshooting
Safety: Unplug the cooler before accessing internal components.
Steps:
- Verify set temperature: Confirm the setpoint is appropriate for wine (typically 40–65°F / 5–18°C). Adjust upward and monitor.
- Power reset: Unplug for 10 minutes to reset the control. If L1 returns and the unit continues to overcool, proceed.
- Check sensors: Inspect and test the cabinet temperature sensor for correct resistance. A sensor reading too high will cause the unit to overcool.
- Inspect control board: Look for a stuck or welded compressor relay on the main control board. If the compressor runs even when the set temperature is reached, replace the board.