Costway Internal Air Circulation Failure

Interior fan not running; cold spots near evaporator and warm spots elsewhere.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator/circulation fan motor, Fan blade obstructed by ice or wiring, Loose fan connector, Control board not sending power to fan

How to Fix / Troubleshooting

Safety: Unplug the cooler before removing interior panels.

Steps:

  • Access fan: Remove the interior rear panel to expose the evaporator/circulation fan.
  • Check for obstructions: Clear any ice, wiring, or insulation blocking the fan. Ensure the blade spins freely.
  • Test fan motor: With a multimeter, check for voltage at the fan connector when the compressor is running. If voltage is present but the fan does not run, replace the fan motor.
  • Control board: If no voltage is present and wiring is intact, the main control board may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator/Circulation Fan Motor
Check Price on Amazon