Danby Continuous Run / Control or Sensor Calibration Issue

Compressor and fans run continuously without shutting off, but temperature is stable

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermistor reading slightly warm, Control board not recognizing setpoint reached, Poor insulation or door seal, Ambient temperature too high

How to Fix / Troubleshooting

Safety: Unplug before testing sensors or the control board.

  • Check ambient conditions: Ensure the cooler is not installed in a very hot room or near heat sources, which can cause long run times.
  • Inspect door seal and insulation: Verify the gasket seals well and that the door is not warped.
  • Test thermistor: Measure the cabinet sensor resistance and compare to actual interior temperature. Replace if readings are inaccurate.
  • Control board: If the sensor is accurate but the compressor never cycles off, the control board may be faulty and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Temperature Sensor (Thermistor)
Check Price on Amazon