Possible Causes
Failed LED backlight, Loose display connector, Faulty display PCB, Low-voltage supply issue on main board
How to Fix / Troubleshooting
Safety: Disconnect power before accessing the display.
- Check brightness setting: Some Danby models allow dimming; verify the display is not set to minimum brightness.
- Access display board: Remove the control panel cover to reach the display PCB.
- Inspect connectors: Reseat the display connector and check for corrosion or damage.
- Measure low-voltage supply: With appropriate caution and tools, verify that the main board is supplying the correct low voltage to the display. If not, the main board may be faulty.
- Replace display board: If power is present but the display remains blank or dim, replace the display PCB.