Door Alignment / Hinge or Gasket Problem
Door does not close properly or pops open slightly after closing
Advertisements
Possible Causes
Misaligned hinges, Warped door, Damaged or compressed gasket, Unit not level
How to Fix / Troubleshooting
Safety: Have someone assist when adjusting the door to prevent it from falling.
- Level the cabinet: Adjust the front leveling legs so the cooler is slightly tilted back. This helps the door close and stay shut.
- Inspect hinges: Check top and bottom hinges for looseness. Tighten screws and ensure hinge brackets are not bent.
- Check gasket: Look for twisted or compressed sections. Warm the gasket gently with a hair dryer and reshape it to improve sealing.
- Adjust door position: Loosen hinge screws slightly, reposition the door for even gaps around the frame, then retighten.
- Replace gasket or hinges: If the gasket is torn or hinges are damaged, replace them with Danby-compatible parts.