dE
Danby Door Open / Door Switch Fault

Display shows dE or door icon; alarm beeps and cooling may stop intermittently

Advertisements

Possible Causes

Door not fully closed, Misaligned door or hinges, Failed magnetic door switch or reed switch, Weak or damaged door gasket

How to Fix / Troubleshooting

Safety: Most checks can be done with power on, but unplug before removing any panels.

  • Check door closure: Ensure shelves or bottles are not preventing the door from closing fully. Adjust shelf positions if needed.
  • Inspect gasket: Look for gaps, tears, or warped sections of the door gasket. Close a sheet of paper in the door at several points; if it pulls out easily, the seal is weak.
  • Check door alignment: Verify the door is level and square with the cabinet. Tighten hinge screws and adjust as needed.
  • Test door switch: Many Danby wine coolers use a magnetic reed switch hidden in the cabinet frame and a magnet in the door. Slowly move a magnet along the frame near the top/side and see if the door alarm clears. If it does, the internal switch may be misaligned or faulty.
  • Replace switch or gasket: If the switch fails to signal door closure, replace the door switch assembly. If the gasket is damaged, replace the door gasket with a Danby-specific part.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch Assembly
Check Price on Amazon