E6
Danby User Interface / Display Board Communication Error

Display shows E6 and temperature cannot be adjusted or readings are erratic

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between UI and main board, Failed display/control panel, Oxidized connectors, Main control PCB communication driver fault

How to Fix / Troubleshooting

Safety: Disconnect power before removing the control panel.

  • Remove control panel: On Danby wine coolers, the touch control/display is usually at the top front or door. Remove screws or clips to access the back of the panel.
  • Check ribbon cable: Ensure the flat ribbon or harness between the UI and main board is fully inserted and not damaged. Reseat both ends.
  • Inspect for moisture: Look for condensation or liquid damage around the control panel. Dry gently and correct any door gasket issues causing excess moisture.
  • Visual inspection: Check the UI board for burnt spots or cracked solder joints at the connector.
  • Test after reseating: Restore power and see if E6 clears and buttons respond normally.
  • Replace faulty board: If the error persists, replace the user interface/display board first. If still unresolved, replace the main control PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

User Interface / Display Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements