F1
Danby
Temperature Sensor Range/Calibration Fault
Display shows F1 and unit may not respond to temperature adjustments
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sensor reading out of allowable range, Incorrect replacement thermistor installed, Loose sensor connection at control board, Control firmware error
How to Fix / Troubleshooting
Safety: Disconnect power before testing or replacing sensors.
- Confirm correct parts: If a sensor was recently replaced, verify it is the correct Danby part number for your model. Incorrect thermistor values can trigger F1.
- Inspect connections: Reseat the thermistor connector at the control board and at the sensor end.
- Measure resistance: Test the sensor at room temperature and compare to Danby’s spec. Replace if significantly off.
- Control reset: After sensor replacement, unplug the unit for several minutes to reset the control, then power up and check if F1 clears.
- Replace control board: If a known-good sensor still causes F1, the main control PCB may be misreading the sensor and should be replaced.