Possible Causes

Failed upper-zone evaporator fan, Blocked upper air vents, Faulty upper-zone thermistor, Air leak at upper door gasket

How to Fix / Troubleshooting

Safety: Disconnect power before accessing the upper-zone panels.

  • Check airflow: Ensure bottles are not blocking upper vents or fan inlets.
  • Access upper evaporator: Remove upper shelves and interior rear panel to inspect the evaporator and fan.
  • Test fan and sensor: Spin the fan by hand and replace if stiff or noisy. Test the upper-zone thermistor and replace if readings are incorrect.
  • Inspect gasket: Check the upper door area for gasket leaks that could let warm air in. Replace gasket if necessary.
  • Reassemble and test: Restore power and monitor upper-zone temperature over several hours.