E5
Della Marta Compressor Overload or Start Circuit Fault

Display shows E5 and the compressor or cooling module does not run even though the set temperature is low.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped compressor overload protector, Failed PTC start relay, Loose compressor wiring, Locked compressor drawing high current

How to Fix / Troubleshooting

Safety: Unplug the wine cooler. The compressor and related parts can be hot; allow them to cool before touching.

  • Access compressor compartment: Remove the rear lower panel to expose the compressor, start relay, and overload protector.
  • Check connections: Verify that the spade terminals on the compressor, PTC relay, and overload are tight and not burnt.
  • Inspect relay and overload: Remove the PTC relay and overload from the compressor pins. Shake the relay gently; if it rattles excessively or shows burn marks, it is likely faulty.
  • Replace start components: Install a new Della Marta compressor start relay and overload protector as a set. Reconnect wiring as originally configured.
  • Test operation: Restore power and monitor. If E5 returns and the compressor hums then clicks off, the compressor itself may be locked and require professional replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay and Overload Protector
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements